1. General

This specification covers the design requirements and performance standards for the supply of optical fiber cables as described below.  The features described in this document are intended to provide information on the performance of the optical cable and aid in handling and installation.  Please refer to the separate fiber specification for details regarding the optical fiber.

1.1 Cable Description

4SProducts Central Tube Fiber Bundle cables contain 2 to 96 optical fibers. The fibers are grouped into bundles held together and identified by colorful thread binders. The fiber bundles are housed in a single gel-filled central buffer tube.  The ADS cable sheath consists of 6 Fiber Reinforced Plastic (FRP) rods, 3 placed longitudinally down each side of the central tube. These strength elements provide the cable with the necessary tensile strength for installation and service loads. Highly visible ripcords are placed along each group of rods for quick and easy sheath entry.  The tube and strength elements are covered with a smooth outer black MDPE jacket.

4SProducts Central Tube Fiber Bundle / Single Jacket optical cables are ideal for low count outside plant applications. Recommended installations include duct and lashed aerial. 
 

1.2 Quality

To meet ISO 9000 standards.

1.3 Reliability

Both initial and periodic qualification testing are performed to assure the cable's performance and durability in the field environment.

To meet industry standards organizations such as Bell Communications Research (Bellcore), Telecommunications Industry Association (TIA), Insulated Cable Engineers Association (ICEA), International Telecommunications Union (ITU), International Electrotechnical Commission (IEC), American Society for Testing and Materials (ASTM), Rural Utilities Service (RUS), and The Institute of Electrical and Electronics Engineers (IEEE).

2. Cable Design

2.1 General

4SProducts Central Tube Fiber Bundle / Single Jacket optical cables utilize a central tube construction which provides for a small diameter cable. The steel armored sheath construction produces a rugged, rodent resistant cable, ideal for direct buried or lashed aerial installations.

APPLICABLE SHEATH TYPES

SHEATH TYPE

PART No.

Single Jacket

FS-XXX*SNDnn

XXX

Denotes Fiber Count

*

Denotes Fiber Type

nn

Denotes Attenuation Values

2.2 Fiber Types

The following fiber types are available in this cable design.  Please refer to the appropriate fiber specification document for details on fiber design and performance.

APPLICABLE FIBER TYPES (*)

Fiber Type

Specification

Designation

Multi mode fiber 50/125 µm G.651 B
Multi mode fiber 62.5/125 µm TIA-492AAA C

Single mode Fiber

G.652

S

Non-Zero Dispersion Shifted (NZDS)

G.655

H
 

APPLICABLE ATTENUATION VALUES (nn)

Fiber Type

Description

Designation

Single mode

0.35/0.25 db/km  1310/1550nm S1
0.40/0.30 db/km 1310/1550nm S2
Non-Zero Dispersion Shifted (NZDS) S3
Custom (Please specify values) S4
Multi mode

62.5/125um, 3.50/1.00 db/km

160/500 Mhz*km, 850/1300nm

M1

62.5/125um, 3.50/1.00 db/km

220/500 Mhz*km, 850/1300nm

M2

2.5/125um, 3.50/1.00 db/km

350/500 Mhz*km, 850/1300nm

M3

62.5/125um, 3.50/1.00 db/km

500/500 Mhz*km, 850/1300nm

M4

50/125um, 3.00/1.00 db/km

500/500 Mhz*km, 850/1300nm

M5

50/125um, 3.00/1.00 db/km

400/400 Mhz*km, 850/1300nm

M6

2.3 Optical Fiber Color Code

The UV acrylate coated fibers are color coded with highly distinguishable, vibrant colors according to the following table.  All colors meet Munsell standards as specified in TIA-359 and TIA-598.

FIBER COLOR CODE

FIBER No.

COLOR

01

Blue

02

Orange

03

Green

04

Brown

05

Slate

06

White

07

Red

08

Black

09

Yellow

10

Violet

11

Rose

12

Aqua

 

THREAD BINDER COLORS

BINDER No.

COLOR

01

Blue

02

Orange

03

Green

04

Brown

05

Slate

06

White

07

Red

08

Black

2.4 Threaded Binders

The colored fibers are grouped together in bundles of either 6 or 12 fibers according to the total fiber count of the cable. For cable counts not evenly divisible by 6 or 12, the remaining odd number of fibers will be placed in a last bundle. The bundles are held together by colorful threads. Two opposite wound threads are used on each bundle to make bundle identification and separation easy.

BUFFER TUBE DIMENSIONS

FIBER PER TUBE

No. Fibers/Bundle

No.

of Bundles

02 - 06

N/A

N/A
07 - 36 06 02 - 06
37 - 96 12 04 - 08

 

2.5 Central Buffer Tube

The fiber bundles are placed in a single, gel filled buffer tube. The gel prevents water migration down the tube and can be easily removed from the bundles with isopropyl alcohol. The buffer tube is made with of a semi-translucent thermo-plastic material.

2.6 Cable Water Blocking

The fiber bundles are placed in a single, gel filled buffer tube. The gel prevents water migration down the tube and can be easily removed from the bundles with isopropyl alcohol. The central buffer tube is wrapped with water absorbing tape to prevent the migration of water through the cable.

2.7 Cable Sheath

The ADS cable sheath consists of 6 Fiber Reinforced Plastic (FRP) rods, 3 placed longitudinally down each side of the central tube. These strength elements provide the cable with the necessary tensile strength for installation and service loads. Highly visible ripcords are placed along each group of rods for quick and easy sheath entry.
The tube and strength elements are covered with a smooth outer black MDPE jacket.
 

2.8 Cable Dimensions

LOOSE TUBE CABLE DIMENSIONS

CABLE TYPE

FIBER COUNT

DIAMETER

WEIGHT

FS-XXX*SNDnn

002 - 048

12.5 mm (0.49 in)

130 Kg/km (87 lbs/kft)

050 - 096

14.5 mm (0.57 in)

166 Kg/km (111 lbs/kft)

Above figures are nominal values; actual production dimensions and weights may deviate slightly from the indicated figures above

2.9 Markings

2.9.1 Cable Markings

 

The entire length of each cable is marked with the following items:

 

bullet

4SProducts Logo

bullet

Year of Manufacture

bullet

4SProducts Part No.

bullet

Fiber Count

bullet

Sequential Length Markings in Meters

bullet

Telephone Handset Symbol

All length markings are placed at one meter intervals.  The actual cable length will be within ±3% of the marked length.  All markings are in indented in permanent white characters.  If remarking is required, yellow markings are used to correct the error in the original markings.

All cable text and markings are in the English language as follows;

 

2.9.2 Tape Markings

 

Non-Hydroscopic tape inside cable will contain the following markings in no more than 50cm distances.

 

bullet

Month / Year of Manufacture

bullet

Purchase Order number

 

2.9.3 Reel Markings

 

The text on the reels is to be printed as follows:

 

bullet

4SProducts Logo

bullet

Cable Type

bullet

Single-Mode X Fiber Count

bullet

Marking Showing Side to Unreel Cable

 

All reels will be painted in 072 royal blue and markings shall be in white.

All reels will contain a securely fastened metal plate with the following information:

 

bullet

Order Number

bullet

Drum Number

bullet

Reel Gross Weight (kg)

bullet

Reel Net Weight  (kg)

bullet

Reel Cable Length (Meters)

3. Performance Matrices

The finished cables can be subjected to the following mechanical and environmental conditions without a permanent increase in attenuation or damage to the cable.

MECHANICAL PERFORMANCE

PROPERTY

TEST PROCEDURE

SPECIFICATION

Low and High Temperature Cable Bend

 EIA/TIA-455-37

20 x cable O.D.
@ -30
°C and 60 °C

Impact Resistance

 EIA/TIA-455-25

25 impact cycles

Compressive Strength:

All-Dielectric

 EIA/TIA-455-41

220 N/cm  (124 lbs/in.)

Armored 440 N/cm  (248 lbs/in.)
Maximum Tensile Load: During Installation EIA/TIA-455-33 2700 N (600 lbs)
During Service 890 N (200 lbs)

Cable Twist

 EIA/TIA-455-85

2 meter length ± 180°

Cable Cyclic Flexing

 EIA/TIA-455-104

20 x cable O.D.
25 cycles

Maximum Bend Radius

During Installation

 EIA/TIA-455-37

20 x cable O.D.

During Service

10 x cable O.D.

Gopher Risitance Bellcore GR-20

Index rating ≤ 3

ENVIRONMENTAL PERFORMANCE Matrix

PROPERTY

TEST PROCEDURE

SPECIFICATION

Temperature:

Operation

 EIA/TIA-455-3

-40 to +70 °C   (-40 to +158 °F)

Installation

-30 to +60 °C   (-22 to +140 °F)

Storage / Shipping

-40 to +75 °C   (-40 to +167 °F)

Cable Aging

 EIA/TIA-455-37

168 hours @ 85 °C

Cable Freezing

 EIA/TIA-455-98

Frozen in Ice

Water Penetration

 EIA/TIA-455-82

1 meter for 24 hours

Compound Drip Temperature

 EIA/TIA-455-81

80 °C (176 °F)

Color Coding Permanence

 Bellcore GR-20

Colors are Stable after Aging

4. Testing & Inspection

The optical properties of all fibers are measured before cable manufacturing and remain traceable throughout the manufacturing process and the lifetime of the cable.

After cabling, 100% of all fibers in each length of cable are measured with bi-directional OTDR at all operating wavelengths.  The attenuation for each fiber is recorded.  Cable dimensional measurements are also made at final inspection and recorded.

5. Packaging & Shipping

Cable is supplied in lengths specified at the time of purchase.  Each length will be shipped on a separate non-returnable wooden reel.  The minimum barrel diameter of the reel will not be less than 30 times the cable diameter.

The cable on each reel will be completely covered with several layers of plastic wrap.  This wrap shall provide excellent protection to cables against moisture during transport or storage.

The cable ends will be sealed with plastic protection to prevent water penetration and the escape of water blocking gel.  The ends will be easily accessible for testing.

Each reel is marked with 4SProducts “Item Part No.”, cable type, fiber count, date of manufacture, and cable length on reel.  A final inspection test report with attenuation performance data for each fiber shall NOT be attached to the reel, but provided via mail to customer.

6. Warranty

4SProducts expressly warrants that all cables furnished shall conform to all specifications and appropriate standards manufactured under and will be new and free from defects in material or workmanship for a period of 36 months from invoice date.  4SProducts conforms that all products will conform to specifications provided and that all goods will be adequately and as agreed contained, packaged, marked, and labeled.  4S Products agrees to place or correct defects of any goods or services not conforming to the foregoing warranty promptly, without expense to its Customers, when notified of such nonconformity by its Customers.