Outside Plant Copper Cable - Exchange Cable

 

(Buried Service Wire - BSW)

 

 

 

Product Description


4SProducts BSWire
®-n is designed for direct burial applications and is available in 2, 3, 4, 5 and 6 pair sizes. The primary application of a Buried Service Wire is service entrances. It is filled with PIB base jelly compound, which is chemically and electrically compatible with all other materials in the wire.  The compound completely coats each insulated conductor and fills the air space between conductors.

 

Physical Description

 

bullet

Conductors: Solid annealed copper in 22 and 24 AWG.

bullet

Insulation: Each conductor is insulated with solid high-density
polyethylene in distinctive colors.

bullet

Core Assembly: Individual conductor dimensions are tightly controlled
to limit resistance unbalance of twisted pairs. Pair twist lays
are varied to minimize crosstalk and meet capacitance unbalance
limits. The wire core is completely filled with PIB base jelly such as BP Naptel 867,
filling the air spaces between insulated conductors.

bullet

Jacket: A black, linear low-density polyethylene jacket is extruded
over the core and ripcord to protect the core from minor mechanical
damage, degradation by sunlight and ingress of moisture and water.

 

Electrical Specifications

 Average Mutual Capacitance at 1000 Hz

max. Individual Wire Avg.

nF/mile

nF/km

94

58

83 ± 7

52 ± 4

Conductor Size

Minimum Insulation Resistance

Conductor DC Resistance

Attenuation @722 kHz

Resistance Unbalance

Dielectric Strength DC Potential – Volts

Max Individual

Max Individual

68 °F (20 °C)

68 °F (20 °C)

Maximum

Minimum

AWG

mm

gigohm / mile

gigohm / km

ohms/mile

ohms/km

dB/kft

dB/km

Individual Pair %

Cdr. to Cdr.

22

0.64

1.0

1.6

91.0

56.4

4.6

15.1

5.0

5,000

24

0.50

1.0

1.6

144.0

89.5

5.8

19.0

5.0

4,000

Far End Crosstalk at 150 kHz

Min. FEXT (dB/kft)

63

Min. FEXT (dB/km)

58

Near End Crosstalk at 772 kHz

Min. NEXT mean (dB)

48

Capacitance Unbalance @ 1000Hz, Pair to Pair

Max. Pair to Pair (pF/kft)

80

Max. Pair to Pair (pF/km)

145

Max. Pair to Ground (pF/kft)

800

Max. Pair to ground (pF/km)

2,625