Copper Clad Steel Shield |
Single Jacket | Filled-Gel
Outside Plant Copper Cable - Exchange Cable
|
|
|
Description
 |
Conductors: Solid annealed copper in 19, 22 and 24 AWG. |
 |
Insulation:
Conductors are insulated with solid polyolefin,
color
coded in accordance with industry standards.
|
 |
Twisted
Pairs: Individual conductors are twisted into pairs with varying
lay lengths to minimize crosstalk and specific color combinations to
provide pair identification.
|
 |
Core Assembly: Cables of 25 pairs or less are assembled into a
cylindrical core. Cables larger than 25 pairs are assembled into units,
which are then used to assemble the core. Units are individually identifiable
by color coded unit binders.
|
 |
Filling Compound: The core assembly is filled with an 80°C ETPR
or
PIB Base Jelly
compound,
completely filling the interstices between the pairs and
under
the core wrap.
|
 |
Core Wrap: A non-hygroscopic, dielectric tape is applied over
the
core assembly to provide protection for the core. |
 |
Shielding:
A corrugated, gopher resistant, copper alloy or copper
clad
steel tape is applied longitudinally with an overlap. The shield interfaces
are flooded with an adhesive compound to provide a moisture
barrier and inhibit corrosion.
|
 |
Jacket:
A black, linear low-density polyethylene jacket is applied overall.
The jacket provides a tough protective covering designed to
withstand exposure to direct sunlight, atmospheric temperature
changes
and stresses expected in standard installations.
|
 |
Jacket Markings: Information, such as manufacturer's
identification, pair count, AWG, product
identification and a telephone handset is printed at 2 ft. intervals
on the cable jacket. Sequential footage markings are printed at
alternate 2 ft. intervals.
|
 |
Optional Designs:
CasFOUR®-F
is available with an internal screen for
use with T-Carrier systems.
CasFOUR®-F
is also available with mechanical protection.
|
|
|
|
|
|
Applications
4SProducts CasFOUR®-F cables are designed for
use in duct or direct burial applications where protection
from moisture is required. CasFOUR®-F cables may be used
aerially, but must be attached to a support strand
(messenger). CasFOUR®-F cables are recommended for use in
high-risk areas where additional mechanical or rodent
protection is required. |
|
|
|
Qualifications & Approvals
Manufactured to meet requirements of ANSI/ICEA
S-84-608-1994: RUS 7 CFR 1755.390 (PE-39). |
|
|
|
Electrical
Specifications |
|
Average
Mutual Capacitance at 1000 Hz |
|
|
|
|
|
|
|
Total
No. of Pairs |
nF/mile |
nF/km |
|
|
|
|
|
|
|
12
or Less |
83
± 7 |
52
± 4 |
|
|
|
|
|
|
|
Over
12 |
83
± 4 |
52
± 2 |
|
|
|
|
|
|
|
|
|
Conductor
Size |
Minimum
Insulation Resistance |
Max
Average Attenuation |
Max
Conductor
Resistance |
Resistance
Unbalance |
Dielectric
Strength
DC Potential –
Volts |
|
68 °F (20 °C) |
|
68 °F (20 °C) |
772
kHz |
68
°F
(20 °C)
Ohms |
Maximum |
Minimum |
|
AWG |
mm |
gigohm
/ mile |
gigohm
/ km |
dB/kft |
dB/km |
mile |
km |
Ave
% |
Individual
Pair % |
Cdr.
to Cdr. |
Cdr
to Gmd. |
| 19 |
0.90 |
1.0 |
1.6 |
2.8 |
9.2 |
45.0 |
28.0 |
1.5 |
5.0 |
7,000 |
15,000 |
| 22 |
0.64 |
1.0 |
1.6 |
4.0 |
13.1 |
91.0 |
56.5 |
1.5 |
5.0 |
5,000 |
15,000 |
| 24 |
0.50 |
1.0 |
1.6 |
5.0 |
16.4 |
144.0 |
89.5 |
1.5 |
5.0 |
4,000 |
15,000 |
|
|
Capacitance
Unbalance Pair to Pair |
|
Pairs |
Maximum
Individual |
Maximum
RMS |
|
pF/kft |
pF/km |
pF/kft |
pF/km |
|
12
or Less |
80 |
145 |
- |
- |
|
mor
than 12 |
80 |
145 |
25 |
45 |
|
Capacitance
Unbalance Pair to Ground |
|
Pairs |
Maximum
Individual |
Maximum
Average |
|
pF/kft |
pF/km |
pF/kft |
pF/km |
|
12
or Less |
800 |
2625 |
- |
- |
|
more
than 12 |
800 |
2625 |
175 |
574 |
|
|